AMC & Validation Support
DAH Healthcare Solution Pvt. Ltd. provides comprehensive Annual Maintenance Contract (AMC) services for cleanrooms, HVAC systems, modular operation theatres, ICUs, and critical cleanroom equipment, ensuring continuous system reliability and performance. Our preventive and corrective maintenance programs are designed to maintain key environmental parameters such as temperature, humidity, airflow, and pressure differentials within specified limits.
In addition to maintenance, DAH offers cleanroom and HVAC validation support to help facilities meet ongoing regulatory and audit requirements. Our validation services include airborne particle count testing, HEPA filter integrity testing (PAO/DOP), airflow volume and velocity measurement, pressure differential verification, and temperature–humidity mapping, conducted in accordance with ISO 14644, WHO-GMP, NABL, and applicable standards.
Backed by strong engineering expertise and field experience, DAH’s AMC and validation support services help clients sustain compliance, minimize downtime, and extend the operational life of cleanroom and healthcare facilities, ensuring that systems continue to perform as designed over the long term.






AMC for Cleanroom Systems
- HEPA/ULPA filter inspection, replacement & DOP testing
- Airflow pattern & ACH verification
- Pressure differential monitoring & calibration
- Temperature & humidity control checks
- Contamination control audits
- Cleanroom wall/partition maintenance
- Modular panel alignment & repairing
- Flooring, door systems & window inspection
- Cleanroom air handling unit servicing
- Recirculation module servicing
AMC for Modular Operation Theatres (OT)
- Laminar airflow canopy servicing
- Sterile Air System maintenance
- HEPA filter integrity tests (Class 100 zone)
- OT pressurization & airflow validation
- Temperature & humidity stability checks
- OT pendants, scrub stations & equipment interface checks
- AHU servicing & filter replacements
- Noise & vibration measurements
- OT sterile zone re-validation
AMC for HVAC Systems (Hospitals, Labs, Commercial & Industrial)
- AHU preventive maintenance
- Coil cleaning, blower servicing & motor alignment
- Filter replacement (Pre, Fine, HEPA)
- Duct cleaning & leakage rectification
- Fresh air module & exhaust unit servicing
- VFD & electrical panel inspection
- Refrigeration cycle checks (for chilled water/VRF systems)
- Temperature & humidity calibration
- BMS/HVAC automation checks
AMC for Cleanroom & Healthcare Equipment
- Laminar Air Flow Workstations
- Reverse Laminar Air Flow Units
- Dynamic Pass Boxes
- Static Pass Boxes
- Air Showers
- Garment Cabinets
- Fan Filter Units
- OT laminar airflow ceilings
- ICU/Isolation room pressure control units
- Sterile air & air purification systems
- MGPS-related airflow components (where applicable)
CLEANROOM TYPES WE DESIGN & EXECUTE
ISO Classes
- ISO 5 / Class 100
- ISO 6 / Class 1,000
- ISO 7 / Class 10,000
- ISO 8 / Class 100,000
Industry-Specific Cleanrooms
- Pharmaceutical cleanrooms
- Biotechnology & tissue culture labs
- Hospital OTs & sterile air systems
- IVF & fertility labs
- Precision engineering
- Semiconductor & electronics
- Food & agriculture labs
- Nuclear & research facilities